Dimensions 150 x 140 x 86mm |
Features |
Model No |
Voltage |
Min Load |
Max Load |
Reg |
SDD-250-24 |
5V |
3A |
30A |
+5/-4% |
|
12V |
1A |
12A |
±5% |
|
-5V |
0A |
8A |
±5% |
|
-12V |
0A |
2.7A |
+10/-8% |
SDD-250-48 |
5V |
3A |
30A |
+5/-4% |
|
12V |
1A |
12A |
±5% |
|
-5V |
0A |
0.5A |
±5% |
|
-12V |
0A |
1A |
+10/-8% |
Specification
Input Voltage SDD-250-24: 19V~32V ; SDD-250-48 : 36V~72V
Input Current SDD-250-24 : <19A@19V DC ; SDD-250-48 : <11A@36V DC
Overload Protection Over 105% ~ 150% of rating, shutdown
Short Circuit Protection Shutdown
Input Protection Ceramic fuse,20A/125V
Input Voltage Protection Shutdown SDD-250-24: Under Voltage Protection: <15V~18V, Over Voltage Protection: >32~36V
Input Voltage Protection Shutdown SDD-250-48: Under Voltage Protection: <30V~35V, Over Voltage Protection: >74~80V
Rise Time <20mS
TTL Signal Power Good Signal
Temperature Operating: -10~70°C; De-rating: 45°C ~70°C : 2.5%/°C. Storage: -10~+75°C
Humidity Operating: 20% ~ 85%; Storage: 10% ~ 95% (Non condensing)
SAFETY UL 60950, CSA C22.2 No.60950, TUV EN 60950, IEC 60950,EMKO- TSE (74-SEC)207/94 Approved.
EMI EN 55022 CLASS B, FCC CFR 47 PART 15 CLASS B, CNS 13438 CLASS B
EMS EN 55024: EN 61000-4-2,3,4,5,6,8