RPD-160B Series
Features Universal AC input Built-in active PFC function Short circuit, over load, over voltage, over temperature protections 5″x3″ compact size Free air convection for 100W and 150W with 20.5 CFM forced air With power good and fail signal output No load power consumption under 0.75W by PS-ON control (Optional) Standby 5V@0.8A with Fan/0.6A without Fan (Optional) Approval: UL / CUL / TUV / CE / CB |
Part Number | Voltage | Current (amps) | Power (watts) |
RPD-160B | 5V | 12A | 160W |
24V | 4A |
Specifications
Input Voltage 90 ~ 264Vac 127 ~ 370 Vdc
Input Frequency 47 ~ 63Hz
Power Factor PF>0.93/230Vac PF>0.98/115Vac at full load
Efficiency 84%
Input Current 1.7A/115Vac 0.9A/230Vac
Inrush Current 35A/115Vac 70A/230Vac, cold start
Leakage Current Earth leakage current <300uA/ 264Vac, Patient leakage current <100uA/264Vac
Rated Power (Convection) 100.2W
Rated Power (20.5CFM) 150.4W
Set Up, Rise Time 1200ms, 30ms/230Vac 2500ms, 30ms/115Vac at full load
Hold Up Time 16ms/230Vac/115Vac at full load
Over Load Protection 105 ~ 135% rated output power