DCDimensions 150 x 140 x 86mm

 

Features
2:1 input range
Input & output isolation
Soft start function, low inrush current
Input over voltage and under voltage protection
Input polarity reverse protection
Over load, over voltage, short circuit, protection
Power good signal
Built-in long life ball bearing fan
100% 50°C burn-in test.

Model No

Voltage

Min Load

Max Load

Reg

SDD-300-24

5V

3A

30A

±5%/-4%

12V

1A

15A

±5%

-5V

0A

8A

±5%

-12V

0A

2.7A

+10/-8%

Specification
Input Voltage                                                    19~32V DC (Typical 24V)
Input Current                                                    <24A @19V DC
Max. Power                                                      300W
Input Protection                                               Ceramic Fuse, 30A/125V
Input Voltage Protection Shutdown under         <15V~18V
Input Voltage Protection Shutdown over           >37V~41V
Overload Protection                                          Over 105% ~ 150% of rating, shutdown.
Short Circuit Protection                                     Shutdown
Rise Time                                                          <20mS
TTL Signal                                                         Power Good Signal
Cooling                                                              Built-in a 36 CFM DC fan
Operating Temperature                                     -10~70°C; De-rating: 45°C ~70°C: 2.5%/°C. Storage: -10~+75°C
Operating Humidity                                           Operating: 20% ~ 85%; Storage: 10% ~ 95% (Non condensing)
MTBF                                                                188K hours

SAFETY                                                            UL 1950 3rd, CSA C22.2 No.950, TUV EN 60950, IEC 60950, EMKO-                                                                               TSE (74-SEC) 207/94 approved.
EMI Standards                                                  EN 55022 CLASS B, FCC CFR 47 PART 15 CLASS B, CNS 13438 CLASS B
EMS Standards                                                EN 55024:EN 61000-4-2,3,4,5,6,8