Dimensions 150 x 140 x 86mm |
Features DC input 12V (9.5V ~ 16V) Input and output isolation Soft start function, low inrush current Input under and over voltage protection Over load, over voltage & short circuit protection Power good signal / PS-ON signal +3.3V & +5V output remote sensing Built-in long life ball bearing fan 100% 50°C burn-in test Meet Intel ATX 2.01 / ATX2.03 UL, cUL, TUV, CB, CE standard |
Model No |
Voltage |
Min Load |
Max Load |
Reg |
SDX-160-12 |
3.3V |
0A |
15A |
±5% |
|
5V |
3A |
20A |
±5% |
|
12V |
0.5A |
7A |
+5/-6% |
|
-5V |
0A |
3A |
±5% |
|
-12V |
0A |
1.5A |
+10/-8% |
|
5Vsb |
0A |
1.5A |
±5% |
Specification
Input Voltage DC 9.5V ~ 16V Typical 12V
Input Current <22.5A @ 12V DC input, full load condition
Input Protection 30A / 125V ceramic fuse
Over Load Protection Over 105% ~ 150% of rating, shutdown. Auto recovery when fault condition has been removed
Over Voltage Protection +5V: +5.8V~+7.0V, +12V: +13.8V~+17.5V. Shutdown. Auto recovery when fault condition been removed
Short Circuit Protection Shutdown. Auto recovery when fault condition been removed
Rise time <20mS
Power Good Signal Power on within 100 ~ 500ms, high level TTL signal release
PS-ON Signal TTL high = power off: TTL low = power on
Cooling A 36CFM (min.) DC ball bearing Fan
Temperature Operating: 0~70°C; De-rating: 45°C ~70°C : 2.0%/°C. Storage: -10~+75°C
Humidity Operating: 20% ~ 85%; Storage: 10% ~ 95% (non condensing)
M.T.B.F 173K hours
SAFETY UL 1950, CSA C22.2 No. 950, TUV EN 60950, IEC 60950, EMKO-TSE (74-SEC)207/94 standard
EMI FCC CFR 47 PART 15 CLASS B, EN 50081-1, CNS 13438 CLASS B.
EMS EN 50082-1 (1997)