DC

Dimensions 150 x 140 x 86mm

Features
High efficiency, high reliability
2:1 input range
input and output isolation
Soft start function, low inrush current
input over voltage and under voltage protection
Over load, over voltage & short circuit protection
+3.3V, +5V main output remote sensing
Meet Intel ATX 2.01 / 2.03
FR4 glass epoxy double side circuit board, meet UL-94V0, which could work in an environment with high vibration
Built-in long life ball bearing fan
100% 50°C burn-in test

Model No

Voltage

Min Load

Max Load

Reg

SDX-300-96

3.3V

0.5A

30A

±5%

 

5V

3A

35A

±5%

 

12V

1A

18A

±5%

 

-5V

0A

0.5A

±5%

 

-12V

0A

1A

±10%

 

5Vsb

0A

1.5A

±5%

Specification
Input Voltage                                                      72V~144V DC
Input Current                                                      <5.9A@72VDC
Input Protection                                                  Ceramic fuse, 8A / 250V
Overload Protection                                           Over 105% ~ 150% of rating, shutdown
Short Circuit Protection                                      Shutdown
Rise Time                                                           <20Ms
TTL Signal                                                          Power Good Signal, PS-ON Input Signal
Cooling                                                               Built-in a 36CFM DC ball bearing fan
Temperature                                                      Operating: -10~70°C; De-rating: 45°C ~70°C: 2.0%/°C;                                                                                                  Storage: -10~+75°C
Humidity                                                             Operating: 20% ~ 85%; Storage: 10% ~ 95% (Non condensing)
MTBF                                                                 188K
EMI Standards                                                   FCC CFR 47 PART 15 CLASS B、EN 55022 CLASS B、CNS 13438                                                                                CALSS B
EMS Standards                                                 EN 55024:EN 61000-4-2,3,4,5,6,8