Dimensions 100 x 180 x 40.5 mm |
Features |
Model No |
Voltage |
Min Load |
Max Load |
Tol |
Power |
Efficiency |
SDX-6200-24 |
3.3V |
0.1A |
15A |
±5% |
130W |
67% |
|
5V |
0.5A |
25A |
±5% |
130W |
67% |
|
12V |
0.2A |
12A |
±5% |
200W |
67% |
|
-5V |
0A |
0.5A |
±5% |
200W |
67% |
|
-12V |
0A |
1A |
+8/-5% |
200W |
67% |
|
5Vsb |
0A |
19V~23V: 1A 24V~32V: 1.5A |
±5% |
200W |
67% |
SDX-6200-48 |
3.3V |
0.1A |
15A |
±5% |
130W |
67% |
|
5V |
0.5A |
25A |
±5% |
130W |
67% |
|
12V |
0.2A |
12A |
±5% |
200W |
67% |
|
-5V |
0A |
0.5A |
±5% |
200W |
67% |
|
-12V |
0A |
1A |
+8/-5% |
200W |
67% |
|
5Vsb |
0A |
2A |
±5% |
200W |
67% |
Specification
Input Voltage 24DC:19~32DC,48DC:36~72VDC
Input Frequency 47Hz~63Hz
Input Current 17A max.@32Vdc,9Amax.@72vdc full load
Input Protection 24V: Ceramic fuse, 20A/125V 48V: Ceramic fuse, 12A/125V
Overload Protection Over 105%~180% of rating, shutdown and recovers after fault has been removed
Short Circuit Protection Shutdown and recovers after fault condition has been removed
Rise Time <20mS
TTL Signal Power Good Signal, PS-ON Input Signal
Cooling A 10CFM (min.) DC ball bearing Fan
Safety UL 1950 3rd, CSA C22.2 No 950-95 3rd, TUV EN 60950, IEC 60950,
EMKO-SE(74SEC)207/94 approved
EMI EN 55022 CLASS B, FCC CFR 47 PART 15 CLASS B, CNS 13 438 CLASS B EMS EN 55024 : EN 61000-4-2,3,4,5,6,8,11