SPD-B30 Series.png  Features
Green-mode designing, meet IEA standard<0.75W (standby state)
Low ripple noise
Over load, over voltage & short circuit protection
AC inlet IEC320-C6
With LED indicator
Non min load requirement
100% 45°C burn-in test
UL, cUL, CB, CE pending
Part Number Voltage Current Power
SPD-B30-05 5V 5A 25W
SPD-B30-7-5 8V 4A 30W
SPD-B30-09 9V 3.34A 30W
SPD-B30-12 12V 2.5A 30W
SPD-B30-15 15V 2A 30W
SPD-B30-18 18V 2A 30W
SPD-B30-24 24V 1.25 30W
SPD-B30-48 48V 1A 30W
Specification
 
Input Voltage                                          Universal full range 90V AC – 264V AC
Frequency                                              47 – 63 Hz
Input Current                                          1.0A max at 100V AC input
Inrush Current                                        <30A@115V / <50A@230V AC input. Cold start at 25°C ambient
Leakage Current                                    <0.5mA@264V AC input
Short Circuit Protection                          Hiccup, recovers automatically after fault condition has been removed.
Rise time                                                <50mS
Hold up time                                           >20mS@230V
Cooling                                                   Natural Cooling
Humidity                                                 Operating: 20% ~ 85%; Storage: 10% ~ 95% (non condensing)
M.T.B.F.                                                 553K hours
SAFETY                                                 UL 60950, CSA C22.2 No.60950, TUV EN 60950, IEC 60950, EMKO-TSE                                                                (74-SEC)207/94 standard
EMI                                                         FCC CFR 47 PART 15 CLASS B, EN 50081-1, CNS 13438 CALSS B