Applications
Non-patient contact medical
General electronics
IT equipment
Industrial
NFM 05 Series Features
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Ultra-miniature size, light weight
Cooling by free air convection
Isolation class
UL60601-1/IEC60601-1/EN60601-1 medical safety approved
No load power consumption<0.5W
100% full load burn-in test
Fixed switching frequency at 67KHz
High reliability

Part Number

Voltage (max)

Current (amps)

Power (watts)

NFM-05-3-3

3.3V

1.25A

4.125W

NFM-05-5

5V

1A

5W

NFM-05-12

12V

0.42A

5.04W

NFM-05-15

15V

0.33A

5W

NFM-05-24

24V

0.23A

6W


Specification

Input Voltage                                        85 ~ 264VAC 120 ~ 370VDC

Input Frequency                                   47 ~ 440Hz
AC Current                                           0.12A/115VAC 0.08A/230VAC          
Inrush Current                                      25A/115VAC 45A/230VAC typically, cold start
Setup, Rise Time                                 1000ms, 20ms/230VAC 1000ms,20ms/115VAC at                                                                full load
Overload Protection                             Above 105% rated output power
Over Voltage Protection                      Protection type shut off
Over Temperature                               Protection Tj 145°C typically (U1) Detect on main                                                                 control IC Shut down o/p voltage, recovers                                                                           automatically after temperature goes down
Working Temperature                         -20°C to +70°C                                                                                                                       (Refer to output load de-rating curve)
Working Humidity                                20 ~ 90% RH non-condensing
Temperature Coefficient                     ±0.03%/°C (0 ~ 50°C)
Withstand Voltage                              I/P-O/P:4KVAC
Isolation Resistance                           I/P-O/P:100M Ohms/500VDC

Description
Featuring class II isolation levels they can be equipped into non-patient contact medical equipment and still comply with class B as per EMI regulations. With energy saving and the environment in mind the no load power consumption is lower than 0.5W so that it complies with the requirements for “green mode” power supplies. Standard functions include short circuit, over load and over voltage protections and over temperature protection is equipped on the whole NFM series. Suitable for use in general medical or for industrial usage that require low leakage current, general electronic applications and low profile IT equipment these on-board type PSU’s can be applied on the main control PCB of the final systems.