PS-15 Series
Applications Telecommunications Automation Control & test equipment Security |
|
Features Universal AC input / Full range Low leakage current <0.5mA Protections: Short circuit/Over load/Over voltage/Over temperature Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 67KHz High reliability |
Part Number | Voltage | Current (amps) | Power (watts) |
PS-15-5 | 5V | 3A | 14W |
PS-15-12 | 12V | 1.25A | 15W |
PS-15-15 | 15V | 1A | 15W |
PS-15-24 | 24V | 1A | 15W |
PS-15-48 | 48V | 0.313A | 15W |
Specification
Input Voltage 85 ~ 264VAC 120 ~ 370VDC
Input Frequency 47 ~ 63Hz
Input current 0.4A/115VAC 0.2A/230VAC
Input Frequency 47~440Hz
Inrush Current 40A/230VAC, cold start
Leakage Current <0.5mA / 240VAC
Setup, Rise Time 5 ~ 24V: 1200ms, 30ms 48V: 1200ms, 75ms at full load
Hold Time 100ms at full load
Voltage Tolerance ±2.0%
Overload Protection Above 105% rated output power
Protection type Hiccup mode, recovers automatically after fault condition is removed
Over Temperature Protection Tj 140°C typically (U1) Detect on main control IC
Protection type Hiccup mode, recovers automatically after fault condition is removed
Working Temperature -10~+60°C (refer to output load de-rating curve)
Working Humidity 20 ~ 90% RH non-condensing
Temperature Coefficient ±0.03%/°C (0~50°C)
Withstand Voltage I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Description
PS-15 is a new member to our open frame product line, designed to fill up the gap of lower wattage units. Complying with worldwide safety and performance standards they bear CB and CE marks. Featuring short circuit, over load, over voltage and over temperature protections these small gadgets securely provide the power source to your system within an economical budget.